石油化工高等学校学报

石油化工高等学校学报 ›› 2023, Vol. 36 ›› Issue (3): 31-36.DOI: 10.12422/j.issn.1006-396X.2023.03.005

• 石油化工 • 上一篇    下一篇

不同热导率下MIL⁃101(Cr)储氢过程的数值模拟研究

李杰1(), 张志强2, 付越3, 陈树军2(), 徐瑶1, 范海旭2   

  1. 1.广东省特种设备检测研究院, 广东 佛山 528000
    2.中国石油大学(华东) 储运与建筑工程学院, 山东 青岛 266580
    3.中国石油大学(华东) 新能源学院, 山东 青岛 266580
  • 收稿日期:2022-09-28 修回日期:2022-11-09 出版日期:2023-06-25 发布日期:2023-06-25
  • 通讯作者: 陈树军
  • 作者简介:李杰(1984⁃),男,硕士研究生,工程师,从事低温容器和氢能装备的检验与研究;E⁃mail:vclijie@qq.com
  • 基金资助:
    国家自然科学基金项目(52176028);广东省特种设备检测研究院科技项目(2021CY?1?02)

Numerical Simulation of Hydrogen Storage Process in MIL⁃101(Cr) with Different Thermal Conductivity

Jie Li1(), Zhiqiang Zhang2, Yue Fu3, Shujun Chen2(), Yao Xu1, Haixu Fan2   

  1. 1.Guangdong Institute of Special Equipment Inspection,Foshan Guangdong 528000,China
    2.College of Pipeline and Civil Engineering,China University of Petroleum(East China),Qingdao Shandong 266580,China
    3.New Energy Institute,China University of Petroleum(East China),Qingdao Shandong 266580,China
  • Received:2022-09-28 Revised:2022-11-09 Published:2023-06-25 Online:2023-06-25
  • Contact: Shujun Chen

摘要:

在MOFs材料储存氢气过程中,由于材料本身热导率低,导致热量聚集,影响氢气储存性能。为了提高吸附材料的导热性能,且兼顾其储氢能力,利用数值模拟的方法,分析了吸附材料热导率的最佳调控范围。结果表明,当吸附材料热导率为0~1.2 W/(m·K)时,储氢罐的最高温度、平均温度和吸氢量随着热导率的提高得到明显的改善;当吸附材料热导率大于1.2 W/(m·K)时,改善效果明显减弱;当吸附材料热导率大于2.0 W/(m·K)时,改善效果几乎消失。因此,吸附材料的最佳热导率应当控制在1.2 W/(m·K)左右。

关键词: MIL?101(Cr), 储氢, 吸附, 热导率, 温度分布

Abstract:

In the process of hydrogen storage by MOFs materials, the low thermal conductivity of the materials leads to heat accumulation,which affects the hydrogen storage performance.In order to improve the thermal conductivity of the adsorbent material and take into account its hydrogen storage capacity, numerical simulation was used to analyze the optimal regulation range of the thermal conductivity of the adsorbent material.The results show that when the thermal conductivity of the adsorbent material is in the range of 0~1.2 W/(m·K), the maximum temperature, average temperature and hydrogen absorption capacity of the hydrogen storage tank are obviously improved with the increase of thermal conductivity.When the thermal conductivity of the material is greater than 1.2 W/(m·K), the improvement effect is significantly weakened; when the material thermal conductivity is greater than 2.0 W/(m·K), the improvement effect almost disappears. Therefore, the optimal thermal conductivity of the adsorbent should be controlled at about 1.2 W/(m·K).

Key words: MIL?101(Cr), Hydrogen storage, Adsorbent, Thermal conductivity, Temperature distribution