Journal of Liaoning Petrochemical University

Journal of Liaoning Petrochemical University ›› 2014, Vol. 34 ›› Issue (3): 71-74.DOI: 10.3696/j.issn.1672-6952.2014.03.018

Previous Articles     Next Articles

Simulation and Analysis of Vertical Scour Way of  Heat Pipe Exchanger Based on FLUENT

Yang Yuman1, Sun Tie1, Yu Enbo1, Zhang Dan2, Liu Hongming1   

  1. (1.Mechanical Engineering Department,Liaoning Shihua University,Fushun Liaoning 113001,China; 2.PetroChina Liaohe Petroleum Exploration Bureau General Petrochemical Plant,Panjin Liaoning 124022,China)
  • Received:2013-07-16 Revised:2014-03-08 Published:2014-06-25 Online:2017-07-14

基于F LUENT的热管换热器纵向冲刷方式模拟

杨郁满1,孙 铁1,于恩播1,张 丹2,刘红明1   

  1. ( 1. 辽宁石油化工大学机械工程学院, 辽宁抚顺1 1 3 0 0 1; 2. 辽河石油勘探局石油化工总厂, 辽宁盘锦1 2 4 0 2 2)
  • 通讯作者: 孙铁( 1 9 6 4 - ) , 男, 硕士, 教授, 从事高效节能石化装备的研究与开发; E - m a i l : 1 5 1 4 1 3 6 6 0 8 8@1 3 9. c o m。
  • 作者简介:杨郁满( 1 9 8 7 - ) , 男, 硕士研究生, 从事高效节能石化装备的研究与开发; E - m a i l : y a n g y u m a n y y m@s i n a. c o m。
  • 基金资助:
    辽宁省自然科学基金项目( 2 0 1 3 0 2 0 1 1 7) ; 抚顺市科技攻关项目( 2 0 1 2 2 7) 。

Abstract: The numerical simulation was used to study the vertical scour way of fluid in the heat pipe exchanger by using CFD software FLUENT, and the flow field parameters such as pressure drop, temperature were analyzed. The results show that fluid pressure drop in the vertical scour way was less than fluid pressure drop in the lateral scour way under the same situation. But the heat transfer effect was poorer. The fluid pressure drop was affected by tube spacing and length in the vertical scour way, and fluid pressure drop was proportional to the tube length. The vertical scour fluid heat transfer effect could be improved effectively when the longitudinal fins were added to the heat pipe, which made the temperature distribution in the flow field be more uniform.

Key words: Heat pipe exchanger, Longitudinal scouring, Numerical simulation, Pressure drop, Fin

摘要: 利用C F D软件F LUENT对流体在热管换热器中纵向冲刷方式进行数值模拟, 对流场中压降、 温度等
参数进行了分析。结果表明, 在相同情况下纵向冲刷时的流体压降小于横向冲刷, 但纵向冲刷时传热效果较差; 纵
向冲刷时流体压降受管间距与热管长度等因素的影响, 并且与热管长度成正比。在热管上加装纵向翅片可有效地
改善流体纵向冲刷的换热效果, 并且使流场内温度分布更为均匀。

关键词: 热管换热器 ,  , 纵向冲刷 ,  数值模拟 ,  , 压降 ,  , 翅片