Journal of Liaoning Petrochemical University
  Journals
  Publication Years
  Keywords
Search within results Open Search
Please wait a minute...
For Selected: Toggle Thumbnails
 
Application of MATLAB PDE Toolbox in the First Problem of Stokes
ZHANG Chun-jing,SHEN Long-she,JI Fu-qiang,YU Li-li
Abstract442)      PDF (888KB)(396)      
 
The first problem of stokes is a kind of common problem in the industrial production field. Traditional similar solution to the first problem of stokes is abstract and beyond understanding. Matlab PDE toolbox can vividly describe the first problem of stokes , output the concrete numerical value of research and vividly show the motion state of some plane. Matlab PDE toolbox provide an intuitive, quick, accurate and vivid numerical solution for the research of viscous flow of outside pipe's fluid medium.
2012, 32 (4): 45-47.
 
Analysis on Liquefaction Station Along Long-Distance LNG Pipeline
LI Zheng-bo,CHEN Bao-dong*,LIU Jie,GUAN Xue-yuan,MO Hai-yuan, ZHANG Chun-jing,DU Yi-peng
Abstract389)      PDF (823KB)(321)      
 
As the declining of oil, coal and other fossil fuel, and the rising of environmental pollution and greenhouse's effect, natural gas, as a kind of high efficient and clean energy, has been given a great attention and favour by the countries all over the world. Natural gas liquefaction and storage technology is key to its use and development. The latest theory research shows that the construction of long distance LNG pipeline is feasible in technology and reasonable in the economy. However the researches of the liquefaction station of long distance LNG pipeline are few. The liquefaction process of the liquefaction station along the long distance LNG pipelines was discussed. Through the analysis on the reverse Carnot cycle, combined with cooling characteristics of refrigerant such as propane, ethylene, methane, liquefaction process of liquefaction station along long-distance LNG pipeline was proposed and related equipments were selected.
2012, 32 (4): 41-44.
Calibration and Error Analysis of Cone Flowmeter
ZHANG Chun-jing, SHEN Long-she, YAN Yong-fei, 
Abstract387)      PDF (201KB)(553)      
hrough in-depth study of factors affecting the accuracy of the flowmeter calibration, such as counting and timing accuracy, the stability of the flow, the standard tank volume measurement methods, the switching speed of the commutator, temperature, and so on, to improve the calibration accuracy, and ensure the results of calibration accuracy. Use this high-precision calibration system, to calibrate the cone flowmeter, and scientific processing of the calibration of the flow coefficient, analysis error accuracy of the calibration results, and ensure the reliability of the calibration data. Flowmeter measurement error less than 3 ‰ can be achieved by field flow measurement requirements. 
2012, 32 (2): 54-57.