混凝土强度对GFRP-混凝土-PVC管柱的轴压影响分析

管海伟1,王文武1,刘 娟1,付 春1,于 洋2   

  1. 1.辽宁石油化工大学石油天然气工程学院,辽宁抚顺113001;2.东北石油大学土木建筑工程学院,黑龙江大庆163318
  • 收稿日期:2016-04-18 修回日期:2016-09-14 出版日期:2016-12-27 发布日期:2016-12-29
  • 作者简介:管海伟(1987-),男,硕士,助教,从事土木工程组合结构研究;E-mail:guanhaiwei16@qq.com。
  • 基金资助:
    黑龙江省教育厅科学技术研究项目(12543023)。

Axial Compression Impact Analysis of the Concrete Strength to GFRP-Concrete-PVC Tube Column

Guan Haiwei1Wang Wenwu1Liu Juan1Fu Chun1Yu Yang2   

  1. 1.College of Petroleum EngineeringLiaoning Shihua UniversityFushun Liaoning 113001China;2.College of Civil and Architecture EngineeringNortheast Petroleum University Daqing Heilongjiang 163318China

  • Received:2016-04-18 Revised:2016-09-14 Published:2016-12-27 Online:2016-12-29

摘要: 在酸碱化学环境和潮湿环境中钢管容易被侵蚀,为提高结构的耐久性和承载力,在研究钢管混凝土柱和GFRP管混凝土柱的基础上,提出了GFRP-混凝土-PVC管新型组合柱。设计了一个GFRP-混凝土-PVC管组合柱,分析了组合柱的轴压力学性能,运用ANSYS对GFRP-混凝土-PVC管组合柱在不同混凝土强度等级下的轴压性能进行了数值分析。分析结果表明,随着混凝土强度的提高,GFRP-混凝土-PVC管组合柱的极限承载力提高,呈非线性变化,但承载力增长的速率减小;随着混凝土强度等级的提高,GFRP外管对核心混凝土的约束套箍效果降低,混凝土强度等级为C30时,组合柱约束能力最大,约束系数为2.31。

关键词: GFRP管, 组合柱, 混凝土强度, PVC管, 约束能力

Abstract:

The steel pipe was eroded easily in the acid alkali chemical environment and damp environment. In order to improve the durability and bearing capacity of the structure, the GFRP-concrete-PVC tube new type composite column was put forward on the basis of the research of steel tubular concrete column and GFRP tube concrete column. The GFRP-concrete-PVC tube column was designed to analyze the composite column axis pressure performance and the ANSYS for GFRP-concrete-PVC tube column was used to analyze the assembly axial compression column numerically.  The results showed that the bigger was the concrete strength, the bigger was ultimate bearing capacity of GFRP-concrete-PVC tube composite column, but the smaller was the increasing-rate of bearing capacity. With the increase of concrete strength, the constraints ferrule effect of GFRP outer tube to core concrete was reduced. The composite column constraint ability was the largest when concrete strength was C30, the ferrule constraint factor was 2.31.

Key words: GFRP(Glass-fiber-reinforced plastic)tube, Combination column, Concrete strength, PVC tube, Constraint ability

引用本文

管海伟, 王文武, 刘 娟, 付 春, 于 洋. 混凝土强度对GFRP-混凝土-PVC管柱的轴压影响分析[J]. 辽宁石油化工大学学报, 2016, 36(6): 51-54.

Guan Haiwei, Wang Wenwu, Liu Juan, Fu Chun, Yu Yang.

Axial Compression Impact Analysis of the Concrete Strength to GFRP-Concrete-PVC Tube Column[J]. Journal of Liaoning Petrochemical University, 2016, 36(6): 51-54.

使用本文

0
    /   /   推荐

导出引用管理器 EndNote|Ris|BibTeX

链接本文: http://journal.lnpu.edu.cn/CN/10.3969/j.issn.1672-6952.2016.06.011

               http://journal.lnpu.edu.cn/CN/Y2016/V36/I6/51