辽宁石油化工大学学报

辽宁石油化工大学学报 ›› 2014, Vol. 34 ›› Issue (2): 61-64.DOI: 10.3696/j.issn.1672-6952.2014.02.016

• 化工机械与计算机 • 上一篇    下一篇

基于ABAQUS的焦炭塔风载荷分析

孟庆娟1,关金华1,杨郁满2,谢腾腾2,孙 铁2   

  1. 1.抚顺职业技术学院机电系,辽宁抚顺113122;2.辽宁石油化工大学机械工程学院,辽宁抚顺113001
  • 收稿日期:2013-11-29 修回日期:2013-12-23 出版日期:2014-04-25 发布日期:2017-07-14
  • 作者简介:孟庆娟(1962-),女,工程师,从事高效石化设备优化设计与运行研究;E-mail:1355982001@qq.com。
  • 基金资助:
    中国石油化工集团公司科技项目(313084)。

Wind Load Analysis of Coke Tower Based on ABAQUS

Meng Qingjuan1, Guan Jinhua1, Yang Yuman2, Xie Tengteng2, Sun Tie2   

  1. (1.Electrical&Mechanical Department,Fushun Vocational&Technical College,Fushun Liaoning 113122,China; 2.Mechanical Engineering Department,Liaoning Shihua University,Fushun Liaoning 113001,China)
  • Received:2013-11-29 Revised:2013-12-23 Published:2014-04-25 Online:2017-07-14

摘要: 风载荷是一种随机载荷,能够引起焦炭塔的振动。为研究风载荷对焦炭塔强度的影响,利用
ABAQUS对焦炭塔进行了风载荷的动态分析,考察了载荷加载过程与卸载之后结构的动态响应。结果表明,在风压
作用下,最大节点位移出现在塔体顶部,最大值为0.79mm,最大应力出现在裙座固支端附近的节点处,最大值为
3.26MPa,不会引起结构的失效;在加载与卸载后的一段时间内,结构沿载荷作用方向产生频率为10Hz的振动,在
外载作用下容易引起结构的共振,造成结构的破坏失效。因此,在焦炭塔的设计及运行中必须充分考虑。

关键词: 风载荷 , 焦炭塔, 动态响应 , 振型叠加 , 诱导振动

Abstract: Wind load is a random load that can lead to the vibration of the coke tower. In order to research the influence on the strength of the coke tower by wind, ABAQUS was used to conduct the dynamic analysis of the wind load and the response of the structure during loading and unloading. The results indicate that, with the effect of wind, the maximal nodal displacement appeared at the top of the tower, which is 0.79 mm|while the maximal stress locate at the node around the skirt, the maximum is 3.26 MPa. Both of the displacement and stress could not cause the failure of the structure. During the loading and unloading, the structure engendered vibration along the loading direction. The vibration frequency was 10 Hz. Under the effect of external loads, it could easily cause the resonance of the structure, which could cause damages to the structure. Therefore it must be taken into consideration during the process of design and operation.

Key words: Wind load, Coke tower, Dynamic response, Modal superposition, Induced vibration

引用本文

孟庆娟,关金华,杨郁满,谢腾腾,孙 铁. 基于ABAQUS的焦炭塔风载荷分析[J]. 辽宁石油化工大学学报, 2014, 34(2): 61-64.

Meng Qingjuan, Guan Jinhua, Yang Yuman, Xie Tengteng, Sun Tie. Wind Load Analysis of Coke Tower Based on ABAQUS[J]. Journal of Liaoning Petrochemical University, 2014, 34(2): 61-64.

使用本文

0
    /   /   推荐

导出引用管理器 EndNote|Ris|BibTeX

链接本文: http://journal.lnpu.edu.cn/CN/10.3696/j.issn.1672-6952.2014.02.016

               http://journal.lnpu.edu.cn/CN/Y2014/V34/I2/61